SICK Safety Switches and Interlocks
SICK / Safety switches and interlocks
Wiring contact-based safety switches in series can hide faults. It is called fault masking, the circuit still appears healthy, and it is the reason a guard chain may not deliver the level it was designed for.
SICK safety switches guard doors, hatches and gates across New Zealand plant. RE magnetic, STR1 RFID, and the i and TR locking devices.
Fault masking, and how to avoid it
The most important thing on this page, because it affects installations that look correct.
When contact-based safety switches are wired in series, a fault in one switch can be hidden by the others. The chain still opens when a guard opens, so nothing looks wrong, and the fault detection the safety level depended on is no longer there.
| Approach | Fault masking risk |
|---|---|
| Contact switches wired in plain series | Yes |
| Series with Flexi Loop and a Flexi Soft controller | Prevented. Each sensor individually monitored |
| RFID switches with OSSD outputs, such as STR1 | Prevented |
Flexi Loop allows series connection while individually monitoring each sensor, which SICK states permits performance level e with no compromise in safety.
So if a machine has six guard switches daisy-chained into one input, that is worth raising. The fix is Flexi Loop or OSSD switches rather than more inputs.
See our Flexi Soft page for the controller side.
An RE switch is not PL e on its own
The second conditional rating worth understanding.
SICK states the RE magnetic switches reach up to performance level e, as long as you are using safety controls that have test pulses.
The test pulses connect to the potential-free contacts of the switch to reliably detect short circuits. Without them, the short circuit is undetected and the achieved level drops.
| Evaluation unit | Provides test pulses |
|---|---|
| Flexi Soft | Yes |
| ReLy safety relays | Yes |
| A plain relay or standard input | No |
So the rating belongs to the combination, not the switch. Same principle as the Schneider Preventa modules on our Preventa page.
If someone specifies a PL e switch and wires it to a standard input, the paperwork and the installation disagree.
The RE magnetic switches
The RE1 and RE2 families cover RE11, RE13, RE15, RE21, RE23 and RE27.
| Item | Specification |
|---|---|
| Principle | Magnetically operated, non-contact, with coded magnetic actuators |
| Response range | Up to 7 mm on the RE13, up to 9 mm across the range |
| Contacts | 2 or 3 |
| Rating | Up to PL e to EN ISO 13849, with a suitable evaluation unit |
| Connection | Plug connector or connected cable |
| Flexi Loop | M12 plug compatible on some variants |
| LED | On the RE27 |
Complementary and equivalent contacts are different
A distinction that decides compatibility.
| Contact arrangement | Switches |
|---|---|
| Equivalent, two normally open | RE13, RE23, RE27 |
| Complementary, one NC and one NO | Other RE variants |
SICK notes that certain accessories can only be combined with magnetic safety switches having equivalent contacts, namely the RE13, RE23 and RE27.
So substituting a complementary switch for an equivalent one changes the circuit behaviour and may not work with what it connects to. Check the contact arrangement, not just the response range.
Why magnetic switches suit washdown
SICK positions them for areas where a high level of contamination occurs.
| Advantage |
|---|
| Simple to clean, enabling high hygiene standards |
| Greater tolerances, so they suit guards that are hard to guide precisely |
| No contact with the actuator, so little wear |
| Low maintenance |
Tolerance to door misalignment is the practical reason these get fitted. A sagging door that trips a mechanical interlock will often keep working with a magnetic switch.
SICK publishes horizontal installation tolerance up to 30 mm on some non-contact devices.
So if a guard is nuisance-tripping because the door has dropped, a non-contact switch is the fix. Adjusting the door is better, and not always possible.
STR1, the RFID switch
Where manipulation protection matters.
| Item | Specification |
|---|---|
| Response range | Up to 14 mm |
| Outputs | 2 OSSD safety outputs |
| Rating | PL e and SIL 3 |
| Active surfaces | Three, so activation from three sides |
| Actuators | Four different sizes |
| Series connection | Up to 30 sensors |
| Diagnostics | Intuitive diagnostic function |
Three coding levels, and one of them is a teach-in
This decides whether a replacement is plug-and-play or needs commissioning.
| Coding | Behaviour |
|---|---|
| Universally coded | Accepts all actuators |
| Uniquely coded | An actuator must be taught in. Only that actuator is then accepted |
| Permanently coded | An actuator must be taught in. Permanent |
Higher coding is what prevents defeating a guard with a spare actuator taped to the frame. That is the whole point of the feature, and EN ISO 14119 requires it where defeat is foreseeable.
Practical consequences:
A universally coded replacement works immediately. A uniquely coded one needs the actuator teaching in.
And a permanently coded switch cannot be re-taught. If the actuator is lost or damaged, you need a new switch as well.
Tell us which coding your installation uses.
Series connection adds response time
A specific and easily missed figure. SICK states that in a safe series connection, each downstream safety switch increases the system response time, and that 0.1 seconds must be added for each sensor to the start-up time.
With 30 sensors in series that is 3 seconds.
That is not a fault, and it is worth knowing before someone chases a machine that seems slow to become ready. It also means a long chain has a longer stop response than a single switch, which feeds into the safety distance calculation.
Locking devices
Where a guard must stay shut until the machine is safe.
| Device | Type | Locking force |
|---|---|---|
| TR10 Lock | RFID interlock, PL e | Up to 3150 N |
| i14 Lock | Electro-mechanical, power to lock or release | Up to 1000 N |
| i110 series | Electro-mechanical | 770 N |
| RFID locking, electromagnet | PL e and SIL 3 | 500 N |
Power to release and power to lock
The principle that decides what happens in a power cut, and they are opposite.
| Principle | On loss of power | Suits |
|---|---|---|
| Power to release | Stays locked. Power is needed to unlock | High inertia machinery that keeps running after a stop |
| Power to lock | Unlocks. Power is needed to hold it shut | Where trapping a person inside is the greater risk |
These are not interchangeable and the choice is a risk assessment decision. A power-to-release device on a machine where someone could be shut in, or a power-to-lock device on a flywheel that coasts for a minute, are both wrong in serious ways.
Check the existing device before ordering. It is the single most important characteristic of a locking device and it is not always obvious from the outside.
Locking force is a real number
From 500 N to 3150 N across the range.
The force has to hold against a determined person. If a guard is being forced and the interlock is failing mechanically, the answer is a higher locking force, not another identical device.
The electro-mechanical switches
| Item | Specification |
|---|---|
| Family | i12S, i16S, i17S, i110S and related |
| Use | Safe and economical door monitoring with retaining force |
| Switching | Slow-action switching elements |
| Housing | Plastic or metal |
| Enclosure | IP67 |
| Type | Type 2 electro-mechanical to EN ISO 14119 |
| Coding level | Low to EN ISO 14119 |
Low coding level matters. EN ISO 14119 treats a low-coded actuator as easier to defeat, which affects what additional measures the assessment requires.
If manipulation is a realistic concern, that is the argument for an RFID switch rather than a mechanical one.
EN ISO 14119
The standard SICK references throughout, covering the design and selection of interlocking devices.
Its central concern is preventing the manipulation and bypassing of protective devices, which is why coding level appears on every SICK safety switch datasheet.
| Coding level | Typical device |
|---|---|
| Low | Electro-mechanical switches with separate actuator |
| Low or high | Magnetic and RFID switches, depending on coding |
| High | Uniquely and permanently coded RFID |
The other families
| Family | Notes |
|---|---|
| TR4 Direct | Rugged safety switch, IP69K, for harsh environments |
| TR10 Lock | RFID interlock with guard locking |
| i10, i14, i15, i110 | Electro-mechanical switches and locking devices |
| Inductive position monitoring | Metal actuation, 4 to 15 mm response, 2 OSSD outputs, PL d |
IP69K is the washdown rating, covering high pressure and high temperature cleaning. In a New Zealand meat plant that is the specification that survives.
Note the inductive position monitoring devices are PL d, not PL e. They monitor safe position rather than guard closure, and the rating reflects that.
Actuators are separate parts
The same trap as every non-contact safety device.
The switch and the actuator are separately ordered. On the STR1 the actuator comes in four different sizes, and on the RE range the actuators are coded magnets.
So if a door has been rehung and only one half is damaged, that is a single part order. Tell us which.
And on a uniquely coded RFID switch, a new actuator has to be taught in. On a permanently coded one it cannot be.
What to send us
The full type code and the 7-digit order number.
Switch, actuator, or both.
The coding level, if it is an RFID switch.
Power to release or power to lock, if it is a locking device.
Contact arrangement, equivalent or complementary, on an RE switch.
What it connects to. Flexi Soft, a safety relay, or a series chain.
Important: safety replacements
Safety switches form part of a machine's certified safety function, and the achieved level depends on the evaluation unit as much as the switch.
A like-for-like replacement preserves the assessment. A substitution may not, particularly across contact arrangements, coding levels or locking principles.
We will supply exactly what you specify. If you ask for an alternative we will say what we believe is equivalent and what differs, but the decision belongs with whoever is responsible for the machine's safety. We are a parts supplier, not your safety engineer.
What we can supply
Current production. RE1 and RE2 magnetic switches, STR1 RFID switches, TR4 and TR10, the i series electro-mechanical switches and locking devices, actuators in all sizes, Flexi Loop hardware and cordsets. Quoted with a delivered lead time.
Actuators separately. Usually the cheaper repair.
Discontinued. Earlier SICK safety switches. Surplus and tested used.
We buy SICK safety switches
Safety switches hold value, and a matched switch and actuator pair is worth more than either alone. Keep them together. See Sell To Us.
Related
SICK overview, Flexi Soft controllers, light curtains and laser scanners.
For safety switches from other brands see Pilz PSEN, ABB Eden, Schneider XCS and Omron.
Send us your part numbers
Tell us whether you need the switch, the actuator or both. And if guard switches are daisy-chained into one input, ask us about Flexi Loop. Quotes in NZD including GST.
Industech is an independent supplier of new, surplus and used industrial automation equipment. We are not an authorised distributor of, approved by, sanctioned by, or affiliated with SICK AG. SICK, Flexi Loop, Flexi Soft and ReLy are trademarks of SICK AG. All trademarks, brand names and part numbers are the property of their respective owners and are used here for identification purposes only. Information on this page is for identification and does not constitute a safety assessment.
Forestry
Manufacturing
Mining
Agricultural
FMCG
Petrochemical
Pharmaceutical
BMS
New
With a great range of the top brands, make us part of your next project.
Asset realization
Ask us about our asset realization program to turn your unused spare parts into cash instead of letting them collect dust on the shelf.
Legacy equipment
With our professional expertise, we can help you source and acquire those elusive legacy parts at competitive prices.
What Makes Us Different?
We make it our business to understand your business
We take the time to understand your needs and goals for your plant or project, with reliability and longevity as our top priorities.
Ethical Pricing
At Industech, we take pride in our ethical pricing structure, ensuring you receive the best value we can offer.
We supply new, surplus and cost-effective alternatives from major industrial brands including:
IFM
- Siemens
- Lenze
- B&R Automation
- ABB
- Rockwell Automation (Allen Bradley)
- Schneider Electric
- Berger Lahr
- PILZ
- Sick
- Emerson Electric
- Festo
- Beckhoff
- Omron Corporation
- General Electric (GE)
- Banner
- Keyence
- HBM and so much more.