Siemens MICROMASTER 430 Inverters
Siemens / Drives / MICROMASTER 430
Every MICROMASTER 430 article number, 7.5 kW to 250 kW. The pump and fan drive.
The MICROMASTER 430 was built for pumps and fans. It has more inputs and outputs than the 420, an operator panel with manual and automatic switchover, load torque monitoring that detects a dry running pump, and motor staging so one drive can control a cascade.
It is discontinued, and it is still running water treatment, dairy, irrigation and HVAC plant across New Zealand. Send us the number off the label.
How to read the number
Take 6SE6430-2UD33-0DA0.
| Part | Meaning |
|---|---|
| 6SE6430 | MICROMASTER 430 |
| U | Without filter. A means internal Class A filter |
| D | 3 AC 380 to 480 V, the only supply range on the 430 |
| 33-0 | 30 kW |
| D | Frame size D |
The power code. First digit is a multiplier: 2 means times 1, 3 means times 10, 4 means times 100. The rest reads as a decimal. So 27-5 is 7.5 kW, 33-0 is 30 kW, 41-3 is 132 kW. A few round rather than match exactly.
Every MICROMASTER 430, 3 AC 380 to 480 V
| Output | Frame | Without filter | Internal filter Class A |
|---|---|---|---|
| 7.5 kW | C | 6SE6430-2UD27-5CA0 | 6SE6430-2AD27-5CA0 |
| 11 kW | C | 6SE6430-2UD31-1CA0 | 6SE6430-2AD31-1CA0 |
| 15 kW | C | 6SE6430-2UD31-5CA0 | 6SE6430-2AD31-5CA0 |
| 18.5 kW | D | 6SE6430-2UD31-8DA0 | 6SE6430-2AD31-8DA0 |
| 22 kW | D | 6SE6430-2UD32-2DA0 | 6SE6430-2AD32-2DA0 |
| 30 kW | D | 6SE6430-2UD33-0DA0 | 6SE6430-2AD33-0DA0 |
| 37 kW | E | 6SE6430-2UD33-7EA0 | 6SE6430-2AD33-7EA0 |
| 45 kW | E | 6SE6430-2UD34-5EA0 | 6SE6430-2AD34-5EA0 |
| 55 kW | F | 6SE6430-2UD35-5FA0 | 6SE6430-2AD35-5FA0 |
| 75 kW | F | 6SE6430-2UD37-5FA0 | 6SE6430-2AD37-5FA0 |
| 90 kW | F | 6SE6430-2UD38-8FA0 | 6SE6430-2AD38-8FA0 |
| 110 kW | FX | 6SE6430-2UD41-1FA0 | - |
| 132 kW | FX | 6SE6430-2UD41-3FA0 | - |
| 160 kW | GX | 6SE6430-2UD41-6GA0 | - |
| 200 kW | GX | 6SE6430-2UD42-0GA0 | - |
| 250 kW | GX | 6SE6430-2UD42-5GA0 | - |
Filters work differently above 110 kW
Every 430 from 7.5 to 90 kW is available with an internal Class A filter as standard. From 110 kW upward there is no internal filter option, and Siemens states the external Class A filter may only be used together with a line commutating choke.
If you are replacing a filtered unit above 90 kW, you need the filter and the choke as separate items. Tell us and we will quote all three.
Frame sizes, dimensions and weights
Useful for panel fit and freight.
| Frame | Power | H x W x D | Weight |
|---|---|---|---|
| C | 7.5 to 15 kW | 245 x 185 x 195 mm | 5.7 kg |
| D | 18.5 to 30 kW | 520 x 275 x 245 mm | 17 kg |
| E | 37 to 45 kW | 650 x 275 x 245 mm | 22 kg |
| F unfiltered | 55 to 90 kW | 850 x 350 x 320 mm | 56 kg |
| F filtered | 55 to 90 kW | 1150 x 350 x 320 mm | 75 kg |
| FX | 110 to 132 kW | 1400 x 326 x 356 mm | 116 kg |
| GX | 160 to 250 kW | 1533 x 326 x 545 mm | 176 kg |
Note the filtered frame F is 300 mm taller than the unfiltered one. If you are swapping an unfiltered unit for a filtered one, check the panel height before you order.
FX and GX units are two-person lifts and ship palletised. Factor that into your delivery.
Operating temperature is lower than you might expect
The 430 runs minus 10 to plus 40 degrees C from 7.5 to 90 kW, and 0 to plus 40 degrees C from 110 to 250 kW. That is lower than the 420, which goes to 50 degrees C. In a hot switchroom this matters, and it is a common cause of nuisance tripping in summer.
Options
The 430 uses the BOP-2 panel, which is specific to this series. The communication modules are shared with the 420 and 440.
| Article number | Option | Fits |
|---|---|---|
| 6SE6400-0BE00-0AA0 | BOP-2, Basic Operator Panel 2 | MM430 only |
| 6SE6400-1PB00-0AA0 | PROFIBUS module | MM420, MM430, MM440 |
| 6SE6400-1DN00-0AA0 | DeviceNet module | MM420, MM430, MM440 |
| 6SE6400-1CB00-0AA0 | CANopen module | MM420, MM430, MM440 |
| 6SE6400-1PC00-0AA0 | PC to inverter connection kit | MM420, MM430, MM440 |
| 6SE6400-0PM00-0AA0 | Panel door mounting kit | All |
| 6SE6400-0GP00-0CA0 | Gland plate, frame size C | MM430 |
Gland plates are integrated as standard on frames D, E and F. Only frame C needs one ordered separately.
Every MICROMASTER ships without an operator panel. The 430 comes with a Status Display Panel only. A BOP-2 is a separate order.
Chokes and filters
| Article number | Item | For frame |
|---|---|---|
| 6SE6400-3CC02-2CD3 | Line commutating choke | C, 7.5 to 11 kW |
| 6SE6400-3CC03-5CD3 | Line commutating choke | C, 15 kW |
| 6SE6400-3CC04-4DD0 | Line commutating choke | D, 18.5 to 22 kW |
| 6SE6400-3CC05-2DD0 | Line commutating choke | D, 30 kW |
| 6SE6400-3CC08-3ED0 | Line commutating choke | E |
| 6SE6400-3CC11-2FD0 | Line commutating choke | F, 55 to 75 kW |
| 6SE6400-3CC11-7FD0 | Line commutating choke | F, 90 kW |
| 6SL3000-0CE32-3AA0 | Line commutating choke | FX, 110 kW |
| 6SL3000-0CE32-8AA0 | Line commutating choke | FX, 132 kW |
| 6SE6400-3TC03-2CD3 | Output choke | C |
| 6SE6400-3TD03-2CD0 | LC filter | C |
| 6SL3000-0BE32-5AA0 | EMC filter Class A | FX, 110 kW |
| 6SL3000-0BE34-4AA0 | EMC filter Class A | FX and GX, 132 kW |
| 6SL3000-0BE36-0AA0 | EMC filter Class A | GX, 250 kW |
Siemens matches chokes and filters by frame size, not just by power. Tell us the drive article number and we will match the accessories correctly.
Before you buy
Filtered drives cannot go on an IT supply. Siemens states plainly that MICROMASTER inverters with an internal filter are not permitted on non-grounded IT mains supplies.
The Y capacitor. On a non-grounded supply the removable Y capacitor must be taken out and an output choke fitted.
Residual current devices. Leakage currents may exceed 30 mA, typically 10 to 50 mA in practice. Trouble-free operation on a 30 mA RCD cannot be guaranteed. A 300 mA device is workable.
Motor cable length. Without an output choke, 50 m shielded or 100 m unshielded up to 90 kW. From 110 kW, 100 m shielded or 150 m unshielded. With the right choke, 200 to 300 m, and up to 450 m unshielded on FX and GX.
Replace or migrate
If a pump is down today, a used or surplus 430 of the same article number gets you running with no reprogramming and no panel changes.
If you are planning ahead, the SINAMICS G120 range is the current equivalent and we can quote it as a distributor. It is not a drop-in. We can supply the new drives, keep the old ones running through the changeover, and take the decommissioned units away.
Send us your article numbers
One drive or a full site list. We will come back with price, condition and lead time. Quotes in NZD including GST.
Industech is an independent supplier of new, surplus and used industrial automation equipment. We are not an authorised distributor of, approved by, sanctioned by, or affiliated with Siemens AG. All trademarks, brand names and article numbers are the property of their respective owners and are used here for identification purposes only.
Forestry
Manufacturing
Mining
Agricultural
FMCG
Petrochemical
Pharmaceutical
BMS
New
With a great range of the top brands, make us part of your next project.
Asset realization
Ask us about our asset realization program to turn your unused spare parts into cash instead of letting them collect dust on the shelf.
Legacy equipment
With our professional expertise, we can help you source and acquire those elusive legacy parts at competitive prices.
What Makes Us Different?
We make it our business to understand your business
We take the time to understand your needs and goals for your plant or project, with reliability and longevity as our top priorities.
Ethical Pricing
At Industech, we take pride in our ethical pricing structure, ensuring you receive the best value we can offer.
We supply new, surplus and cost-effective alternatives from major industrial brands including:
IFM
- Siemens
- Lenze
- B&R Automation
- ABB
- Rockwell Automation (Allen Bradley)
- Schneider Electric
- Berger Lahr
- PILZ
- Sick
- Emerson Electric
- Festo
- Beckhoff
- Omron Corporation
- General Electric (GE)
- Banner
- Keyence
- HBM and so much more.